Hydac
MA Series Single Gauge Isolator
MA Series Single Gauge Isolator
Key Features
- Gauge life is extended by using the MA 1 when reading pressure. When not reading pressure, the gauge is vented to tank to protect the gauge against pressure from the system.
- There are two ways to operate the MA 1:
- Push to read (spring return)
- Push and rotate clockwise to lock in for continuous pressure reading
Mounting
- Panel installation maximum 0.39”
Connections
- 1/4” NPT, SAE-5, or G1/4 (Ports M, P, T)
Weight
- 0.88 lbs./0.4 kg
Mounting Position
- Horizontal or Vertical
Operating Fluid
- Mineral Oils
Hydraulic Data
Operating Pressure
- P max. 5075 psi/350 bar (T-Port max. 145 psi/10 bar)
Temperature Range
- -4° to 176°F (-20° to 80°C)