Parker Pneumatic
PXPA11 Two-Hand Control Module

Key Features

  • Poppet – snap-acting (no spools)
  • Same air as in cylinders – Filtration: 40 micron
  • No lubrication required
  • Two-hand control module provide an output signal upon nearly concurrent operation of two pushbuttons. 
Click to Enlarge

PXP-A11

Air Quality –

Standard Shop Air, Lubricated or Dry, 40m Filtration

Flow at 90 PSI (6 bar) in SCFM (l/mn ANR).............. 7 (200)

Materials –

Body.......................................................................Polyamide

Operating Head....................................... Zinc Alloy & Plastic

Nominal Bore Ø in Inches (mm)........................... 7/64" (2.5)

Number of Operations with Dry Air at 90 PSI (6 bar) and

68°F (20°C) - Frequency 1 Hz.............1 million Operations

Operating Positions........................................... All Positions

Operating Pressure.................... 40 to 115 PSIG (3 to 8 bar)

Ports –

5/32" Instant for Semi-Rigid Nylon or Polyurethane Tube

Temperature –

Operating..............................32°F to 122°F (0°C to + 50°C)

Storage............................ -22°F to 140°F (-30°C to + 60°C)

Vibration resistance:

Conforms to section 19-2 of bureau Véritas regulations (November 1987)