Hydac
Diesel Filters

Model Series

  • Diesel PreCare HDP up to 600 l/h
Click to Enlarge

Mobile machines and commercial vehicles are subject to the toughest working conditions all over the world. To ensure smooth running of vehicles and to protect both the engine and the whole drive system from damage, optimum diesel fuel conditioning is particularly important. With its new Diesel PreCare, HYDAC offers a modern system for diesel filtration which protects vehicle manufacturers and operators from failures, breakdowns and expensive service interventions.

Our solution "HYDAC Diesel PreCare", is a cup filter system available in two versions:

Manual water discharge (BestCost design)

The conventional, operator-dependent solution.

Fully automatic discharge Plug & Play (High Tech design)

The innovative solution for fully automatic dewatering, independent of the operator, even during suction-side operation.

Outstanding performance data achieved by 2-stage water removal and superb fi ltration characteristics through the use of synthetic media - these are the special features of these filters.

Both systems are designed for use as pre-filters on the suction-side and as such protect all the pumps and components in the fuel system from water and contamination.

  • Flow rate: BestCost design: up to 600 l/h
  • HighTech design: up to 600 l/h
  • Temperature range: BestCost design: -40 °C to +90 °C
  • HighTech design: -20 °C to +90 °C
  • Nominal voltage: 24 V DC (option 12 V)
  • Rated power Fuel preheating: 300 W
  • Filtration rating: Various (Standard: 10 um)
  • Water separation efficiency: > 95 % to ISO CD 16332
  • Operating pressure: <1 bar (suction-side application)

BestCost Design

  • Inlet: M22x1.5
  • Outlet: M22x1.5
  • Water discharge: manual drain plug
  • Available in 2 sizes: HDP BC 340 and HDP BC 600

HighTech Design

  • Inlet: G3/4
  • Outlet: G3/4
  • Water discharge: Automatic discharge unit (including electronic control, safety valve, pump and water sensor)