Parker Fluid Connector Group
HJK Highjack® Jackline Hybrid Hose
HJK Highjack® Jackline Hybrid Hose
Key Features
- 10,000 PSI Jack Hose
Certifications
- MSHA Accepted
- Meets I J-100 Requirements
Models Available
- HJK04
Applications
- Used for high pressure jackline applications
- Not for high impulse applications
Construction
- Tube: Copolyester
- Reinforcement: Two braids of High Tensile Wire
- Cover: Smooth synthetic rubber
Operating Parameters
Temperature Range:
- -40°F to +150°F (-40°C to +65°C)
(Limited to +135°F (+57°C) for synthetic hydraulic fluids
and water-based fluids)
- Change in working length @ Rated WPSI: ±2%
- Min. Burst Pressure is 3x Max. Working Pressure at 73°F (23°C)
Fittings
- HY Series – pg. E-87 (HY Fittings available
from Parker Hose Products Division)
- Connection configurations limited to:
- -Male Pipe (01)
Colors
- Black
Notes
- Factory-made assemblies only
Catalogs
Catalog Pages
204.4 kB