Parker Fluid Connector Group
580N/H580N/588N Series High Pressure Hose

Key Features

  • Twin and multi-line available
  • Lighter weight and smaller O.D. than 100R2

Certifications

  • Meets or Exceeds SAE 100R8 specifications
  • 580N MSHA Approved
  • 588N Meets SAE J517 for less than 50 micro-amps leakage under 75,000 volts per foot
Model Series

  • 580N-4
  • 580N-6
  • 580N-8
  • 580N-10
  • 580N-12
  • 580N-16 
  • H580N-16*
  • 588N-4
  • 588N-6
  • 588N-8
  • 588N-10
  • 588N-12
  • 588N-16

Click to Enlarge

Applications

  • Hydraulic and pneumatic circuits and systems
  • Replaces 100R2 rubber hose wherever greater flexibility, fluid compatibility, and cover durability are required

Construction

  • Tube: Nylon
  • Reinforcement: Fiber
  • Cover: Polyurethane

Operating Parameters

Temperature Range:

  • -40°F to +212°F (-40°C to +100°C)
  • Change in working length @ Rated WPSI: ±2%
  • Min. Burst Pressure is 4x Max. Working Pressure at 73°F (23°C)

Fittings

  • 58 Series – pg. E-12
  • 58H Series – pg. E-41
  • For Crimp Die Selection charts see pgs. G-30 : G-41
  • Crimp information can be found online, for most Parker products, at www.parker.com/crimpsource

Colors

  • Black
  • Orange (Non-Conductive)

Notes

  • Perforated cover - 580N
  • *Non-perforated cover -588N, H580N-16