Key Features
- RemoteWatchTM Software - virtual control, diagrams and graphics
- Star Watch® ready with 68 channels of data and over 60 process values
- Temperature and pressure instrumentation package
- Energy Management PowerLocTM dewpoint digital readout with Power Save (optional)
- Two extra user defined 4-20 mA or 1-5 Vdc inputs with setpoints and alarms for connection to your flow meter, power meter, etc.
- Intelligent display with operational information
- Full system retentive alarm network (event) log
- Programmable process set points
- Dryer operating “state” annunciation display
- Automatic data logging 24/7, 365 days of all operational information • 16 Channel “programmable” common alarm
- RS-232 communications port (Optional RS-485)
- Access system via Star Watch® or Modbus protocols
- UL Rated Components
- 160 Fields of operational information
- Dual Mode communications. Modbus Protocol, and Star Watch® Protocol
- Connectivity: telco line and cellular wireless modem
- Ethernet (optional)
Performance Characteristics | |
---|---|
Dryer Technology | Desiccant, Externally Heated |
Brand | Airtek |
Pre-installed Optional Accessories | Pre and After Filtration |
Connection Type | 1? NPT , 1 1/2? NPT, 1 1/2" NPT, 2" NPT, 3" Flg, 4" Flg, 6" Flg, 8" Flg |
Maximum Flow Rate (m³/h) | 170, 229, 340, 425, 510, 680, 850, 1019, 1359, 1699, 2038, 2548, 3398, 4417, 5097, 6796, 8495, 10194, 13592 |
Rated Inlet Pressure (psi) | 100.0 |
Maximum Operating Pressure (psi) | 150, 135 |
Minimum Operating Pressure (psi) | 80 |
Maximum Operating Temperature (F) | 120 |
Minimum Operating Temperature (F) | 50 |
Maximum Ambient Temperature (F) | 120 |
Minimum Ambient Temperature (F) | 40 |
Purge Rate | 7, 9.45, 14, 17.5, 21, 28, 35, 42, 56, 70, 84, 105, 140, 182, 210, 280, 350, 420, 560 |
Weight (lb) | 680, 720, 920, 1180, 1370, 1400, 2060, 2350, 3035, 4195, 5215, 7765, 8565, 11562, 12002, Consult Factory |
Width (inch) | 31, 40, 43, 47, 50, 52, 63, 74, 78, 96, Consult Factory |
Depth (Inch) | 18, 22, 27, 28, 35, 41, 60, Consult Factory |
Height (inch) | 83, 85, 87, 88, 89, 92, 93, 102, 113, 110, 112, Consult Factory |
Prefilter Part Number | JC0110-C, JC0150-C, JC0250-C, JC0350-C, JC0450-C, JC0625-C, JC0800-C, JC1000-C, JLA1603-C, JLA2100-C, JLA3200-C, JLA3206-C, Consult Factory |
After Filter Part Number | JC0150-FH, JC0250-FH, JC0350-FH, JC0450-FH, JC0625-FH, JC0800-FH, JC1000-FH, JLA1800-FH, JLA2600-FH, JLA3506-FH, Consult Factory |
Prefilter Replacement Element | JE-CC0110, JE-CC0150, JE-CC0350, JE-CC0450, JE-CC0625, JE-CC0800, (2) JAE3-C, (3) JAE3-C, (4) JAE3-C, Consult Factory |
Afterfilter Replacement Element | JE-FC0150-HT, JE-FC0350-HT, JE-FC0450-HT, JE-FC0625-HT, JE-FC0800-HT, JAE4-FH, (2) JAE4-FH, (3) JAE3-FH, Consult Factory |
Installed Condensate Drain | Timed Solenoid Drain, Demand Solenoid Drain |
Type | Heated |